3-6 Riverstone Networks RS 32000 Switch Router Getting Started Guide
Installing the Hardware Hardware Installation
Warning Use a single-phase grounded power source located within 6 feet (1.89 meters)
of the installation site.
Warning High leakage current can be caused by multiple power supplies. For this
reason, it is essential that each power cord be connected to separate branch
circuits with proper earth connections.
3.3.4 Installing DC Power Supplies
Warning The RS 32000 with DC power supplies should be installed only in Restricted
Access Areas (Dedicated Equipment Rooms, Electrical Closets, or the like)
in accordance with Articles 110-26 and 110-27 of the 1999 National
Electrical Code ANSI/NFPA 70.
To install a DC power supply in the RS 32000 perform the following steps. For DC power supply environmental
specifications, see Table 3-4. For special DC power safety considerations, see Table 3-3.
1. Ensure that the DC power supply is not powered on or connected to its DC power supply source.
2. Position the power supply between two guides, making sure that the groove at the bottom of the
power supply aligns with the guide underneath it (see Figure 3-3).
3. Slide the DC power supply all the way into the slot, firmly but gently pressing to ensure that the pins
on the back of the power supply are completely seated in the backplane.
4. Using a straight-blade screwdriver, turn the screw on the power supply’s front panel clockwise 180
degrees to lock the power supply into the chassis.
Table 3-2 AC power supply environmental specifications
Specification Measurement
Operating Temperature +5° to +40°C (41° to 104°F)
Non-operating Temperature -30° to +73°C (-22° to 164°F)
Operating Humidity 15% to 90% (non-condensing)